Material wear of polymeric tracheostomy tubes: A six-month study
School of Chemical Science and Engineering, Fiber, and Polymer Technology, Royal Institute of Technology (KTH), Stockholm.
Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Anaesthesia and Intensive Care, Stockholm.ORCID-id: 0000-0003-1445-900X
Sophiahemmet University College, Stockholm.
Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Anaesthesia and Intensive Care, Stockholm.
Vise andre og tillknytning
2009 (engelsk)Inngår i: The Laryngoscope, ISSN 0023-852X, E-ISSN 1531-4995, Vol. 119, nr 4, s. 657-664Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

OBJECTIVES: The objectives were to study long-term material wear of tracheostomy tubes made of silicone (Si), polyvinyl chloride (PVC), and polyurethane (PU) after 3 and 6 months of clinical use.

STUDY DESIGN: The study has a prospective and comparative design.

METHODS: Nineteen patients with long-term tracheostomy, attending the National Respiratory Center in Sweden, were included, n = 6 with Si tubes, n = 8 with PVC tubes, and n = 5 with PU tubes. The tubes were exposed to the local environment in the trachea for 3 and 6 months and analyzed by scanning electron microscopy, attenuated total reflectance Fourier transform infrared spectroscopy, and differential scanning calorimetry.

RESULTS: All tubes revealed severe surface changes. No significant differences were established after 3 or 6 months of exposure between the various materials. The changes had progressed significantly after this period, compared to previously reported changes after 30 days of exposure. The results from all analyzing techniques correlated well.

CONCLUSIONS: All tubes, exposed in the trachea for 3-6 months, revealed major degradation and changes in the surface of the material. Polymeric tracheostomy tubes should be changed before the end of 3 months of clinical use.

sted, utgiver, år, opplag, sider
Wiley-Blackwell, 2009. Vol. 119, nr 4, s. 657-664
Emneord [en]
long-term tracheostomy, tracheostomy tube, polymeric materials, material wear, material degradation, biofilm formation
HSV kategori
Identifikatorer
URN: urn:nbn:se:rkh:diva-490DOI: 10.1002/lary.20048OAI: oai:DiVA.org:rkh-490DiVA, id: diva2:606329
Tilgjengelig fra: 2013-02-19 Laget: 2013-02-18 Sist oppdatert: 2019-08-30bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Björling, Gunilla

Søk i DiVA

Av forfatter/redaktør
Björling, Gunilla
I samme tidsskrift
The Laryngoscope

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 484 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • harvard-anglia-ruskin-university
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf