Material wear of polymeric tracheostomy tubes: A six-month study
School of Chemical Science and Engineering, Fiber, and Polymer Technology, Royal Institute of Technology (KTH), Stockholm.
Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Anaesthesia and Intensive Care, Stockholm.ORCID-id: 0000-0003-1445-900X
Sophiahemmet University College, Stockholm.
Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Anaesthesia and Intensive Care, Stockholm.
Visa övriga samt affilieringar
2009 (Engelska)Ingår i: The Laryngoscope, ISSN 0023-852X, E-ISSN 1531-4995, Vol. 119, nr 4, s. 657-664Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

OBJECTIVES: The objectives were to study long-term material wear of tracheostomy tubes made of silicone (Si), polyvinyl chloride (PVC), and polyurethane (PU) after 3 and 6 months of clinical use.

STUDY DESIGN: The study has a prospective and comparative design.

METHODS: Nineteen patients with long-term tracheostomy, attending the National Respiratory Center in Sweden, were included, n = 6 with Si tubes, n = 8 with PVC tubes, and n = 5 with PU tubes. The tubes were exposed to the local environment in the trachea for 3 and 6 months and analyzed by scanning electron microscopy, attenuated total reflectance Fourier transform infrared spectroscopy, and differential scanning calorimetry.

RESULTS: All tubes revealed severe surface changes. No significant differences were established after 3 or 6 months of exposure between the various materials. The changes had progressed significantly after this period, compared to previously reported changes after 30 days of exposure. The results from all analyzing techniques correlated well.

CONCLUSIONS: All tubes, exposed in the trachea for 3-6 months, revealed major degradation and changes in the surface of the material. Polymeric tracheostomy tubes should be changed before the end of 3 months of clinical use.

Ort, förlag, år, upplaga, sidor
Wiley-Blackwell, 2009. Vol. 119, nr 4, s. 657-664
Nyckelord [en]
long-term tracheostomy, tracheostomy tube, polymeric materials, material wear, material degradation, biofilm formation
Nationell ämneskategori
Omvårdnad Materialteknik
Identifikatorer
URN: urn:nbn:se:rkh:diva-490DOI: 10.1002/lary.20048OAI: oai:DiVA.org:rkh-490DiVA, id: diva2:606329
Tillgänglig från: 2013-02-19 Skapad: 2013-02-18 Senast uppdaterad: 2019-08-30Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Björling, Gunilla

Sök vidare i DiVA

Av författaren/redaktören
Björling, Gunilla
I samma tidskrift
The Laryngoscope
OmvårdnadMaterialteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 484 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • harvard-anglia-ruskin-university
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf